118

Error E118 - Primary System Water Pressure Too Low

Baxi · Duo-tec 2 Combi GA Boilers

What does 118 mean?

The central heating system pressure is too low, indicated by the gauge reading below 1 bar or the E118 error code on the display. The boiler will not operate correctly until the pressure is restored.

Common Causes

  • Minor leaks in the heating system
  • Normal pressure loss over time
  • Insufficient water added during initial system filling

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Locate the filling loop, which consists of two taps and a separate copper pipe.

  2. 2

    Connect the copper pipe between the two taps and tighten the nuts securely.

  3. 3

    Fully open one tap, then carefully open the second tap while watching the pressure gauge (or press 'R' 6 times to view on display).

  4. 4

    When the gauge reads between 1 and 1.5 bar, turn both taps off completely and disconnect the copper pipe.

  5. 5

    If the pressure drops again frequently after repressurising, contact your installer for inspection.

Browse all codes in this manual (28)