5395

Alarm Z1 Internal compressor driver fault 1 — Compressor driver issue

Bosch · Alarm List A/W Split (8754) 2018 01 10

What does 5395 mean?

This alarm occurs if 3 specific warnings (code 5394) are logged within 3 hours, or if the warning is active for 30 minutes. It indicates a problem with the compressor's internal driver.

Common Causes

  • Incorrect setting on the heat pump's rotary encoder.
  • Electrical fault in the compressor.
  • Defective inverter.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check and compare the rotary encoder setting (P=4 or P=6) with the manual's definition.

  2. 2

    Measure resistance between compressor windings and earth. If less than 10 kOhm, replace the compressor.

  3. 3

    If the issue persists after checking the compressor, consider replacing the inverter.

Browse all codes in this manual (60)