5506

Alarm Z1 Compressor does not start — Compressor start failure

Bosch · Alarm List A/W Split (8754) 2018 01 10

What does 5506 mean?

This alarm is issued if the compressor has not started within 2 minutes after a start signal was sent. It suggests an issue with the compressor's connection, the inverter, or an internal error.

Common Causes

  • Intermittent connection in the cabling between the inverter and the compressor.
  • Temporary malfunction in the inverter.
  • Internal error in the inverter.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check and ensure a proper, secure connection of the cabling between the inverter and the compressor.

  2. 2

    Break power to the heat pump by turning it off and then on again (reset).

  3. 3

    If the alarm persists after a reset, the inverter is likely defective and needs replacement.