5594 / H01

Alarm Z1 Air in the system — Air detected in the system

Bosch · Alarm List A/W Split (8754) 2018 01 10

What does 5594 / H01 mean?

This alarm indicates that the temperature of sensor TC1 has increased too rapidly (> 0.8 K/s) under normal working conditions. It's mainly for units with an integrated 9 kW electrical heater and is blocked in software v1.09 when TC0>TC1.

Common Causes

  • The flow is blocked by a valve.
  • The flow is blocked due to a bad electrical connection to the circulation pump.
  • Air in the appliance or heating system.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Wait two minutes for the appliance to cool down.

  2. 2

    Check for any closed valves that might be blocking the flow.

  3. 3

    Ensure the circulation pump is running and check its electrical connection.

  4. 4

    If no blockages are found, redo the filling and venting procedure to remove air from the appliance and heating system.