What does 5350 mean?

The compressor motor failed to synchronize after five start attempts. This could be due to cabling issues, oil or liquid in the compressor, a bad sensor reading, or incorrect rotary encoder settings.

Common Causes

  • Bad cabling connection between the inverter and compressor.
  • Oil or liquid present in the compressor during a start attempt.
  • Bad temperature reading from compressor sensor TR1.
  • Improper setting of rotary encoders (A- and P-selectors) on the I/O module.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the cabling and connections between the inverter and the compressor for any loose wires.

  2. 2

    Verify that the A- and P-selectors (rotary encoders) on the I/O module are set according to your wiring diagram.

  3. 3

    If the warning persists, contact a qualified technician to check the compressor sensor TR1 reading and inspect for oil/liquid in the compressor.