5432

Warning Z1 Low pressure sensor JR0 open circuit — Low pressure sensor voltage below 0.5 V DC

Bosch · Compress 7000 Heat Pumps

What does 5432 mean?

This warning indicates that the voltage on terminal 17 on the I/O module is below 0.5 V DC. This typically suggests a poor connection, a defective pressure sensor JR0, or a faulty I/O module.

Common Causes

  • Poor connection in cabling or terminal 17,19 on the I/O module.
  • Defective pressure sensor JR0.
  • Defective I/O module.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the cabling and terminal connections (17 and 19) on the I/O module, ensuring they are secure.

  2. 2

    If the warning persists, contact a qualified technician to measure voltage between terminals 19 and 17 with the sensor disconnected.

  3. 3

    Do not attempt to replace sensors or I/O modules yourself unless you are a qualified installer.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026