4/p/

Blocking fault 4/p/ (2/2/1) - Safety temp sensor contacts interrupted

Buderus · Logamax plus Boilers

What does 4/p/ mean?

The contacts for the safety temperature sensor have been interrupted, indicating an open circuit or loose connection. This safety fault stops heating and domestic hot water. This is a blocking fault, requiring a manual reset.

Common Causes

  • Open circuit in sensor wiring
  • Loose connection
  • Faulty safety temperature sensor

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Press the 'Reset' button on the BC10 basic controller.

  2. 2

    Check any accessible connections to the safety temperature sensor for looseness.

  3. 3

    If the fault reoccurs, contact a qualified service technician to inspect the sensor and its wiring.