6/a/

Blocking fault 6/a/ (2/2/7) - Insufficient ionization current after 4 startup attempts

Buderus · Logamax plus Boilers

What does 6/a/ mean?

After four attempts to ignite, the boiler still detects an insufficient ionization current. This indicates a persistent problem with the burner lighting correctly, preventing heating and domestic hot water. This is a blocking fault, requiring a manual reset.

Common Causes

  • Persistent ignition fault
  • Gas supply issue
  • Faulty electrode
  • Dirty burner
  • Control unit issue

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Press the 'Reset' button on the BC10 basic controller.

  2. 2

    Verify that the gas isolation valve to the boiler is fully open.

  3. 3

    If the fault reoccurs, contact a qualified service technician to inspect the burner and ignition system.