a/1/8

a/1/8 (sub-code 8/2/5) — Conflicting Controller Addresses

Buderus · Logamax plus Boilers

What does a/1/8 mean?

This locking fault occurs when both RC20 and RC35 remote controls are set as Master controllers. Both controls are trying to manage heating circuit 1 and Domestic Hot Water (DHW), leading to incorrect operation of the heating system.

Common Causes

  • RC20 and RC35 remote controls are both configured as Master units.
  • Conflicting address settings between RC20 and RC35 controllers.
  • Incorrect setup of heating programs and room temperatures.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the settings for both RC20 and RC35 remote controls.

  2. 2

    Ensure only one remote control (RC20 or RC35) is configured as the Master for heating circuit 1 and DHW.

  3. 3

    Consult the installer or manual to adjust the address settings for the remote controls.

Browse all codes in this manual (43)
Verified technical data. Last updated: April 2026

Related Faults

--/Flashing --/ - Communication fault between UBA 3 and BC10 controller0/y/Locking fault 0/y/ (2/8/5) - Return temperature sensor detected over 203°F (95°C)1/a/Blocking fault 1/a/ (3/1/6) - Flue gas sensor temperature too high