CodeRegistry
Marcas
  1. Inicio
  2. GE Appliances
  3. Air Conditioning
  4. 45
About·Privacy·Terms

CodeRegistry — Tu biblioteca global de soluciones técnicas.

Por su seguridad, siga siempre los manuales oficiales del fabricante. CodeRegistry es un sitio independiente y no está afiliado a las marcas citadas.

45

Error 45 — Low pressure detected in system

GE Appliances · Air Conditioning

¿Qué significa 45 ?

This error indicates that the system has detected low pressure. It triggers when the minimum temperature of indoor or outdoor pipes is too low during cooling mode, or specific outdoor temperatures are too low during heating mode.

Causas comunes

  • Low pressure sensor detection value is incorrect
  • Low refrigerant charge
  • System air leakage
  • Blocked low pressure or liquid line piping
  • Outdoor heat exchanger electronic expansion valve failure during heating
  • Operation environment is beyond the allowed range

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check if the pressure switch wiring connection is okay.

  2. 2

    Use a multimeter to check the high pressure switch. See if it is short-circuited.

  3. 3

    Check if the EEV coil wiring is correct and firmly in place.

  4. 4

    Open the service valve and check if the piping system is clogged or if the connection pipe is bent.

  5. 5

    If the pressure switch is bad, replace it. If the sensor is bad, replace it.

Ver todos los códigos en este manual (62)
Datos técnicos verificados. Última actualización: April 2026

Fallas relacionadas

1Error 1 — Outdoor PCB EEPROM fault10Error 10 — Defrost sensor fault11Error 11 — Compressor suction temperature sensor fault
Fuente: GE Appliances Air Conditioning
Open Manual (Page 34)Buscar más códigos en este manual