¿Qué significa H5 ?

IPM protection error means the drive processor's supply voltage is low, or the IPM module is malfunctioning. The system will shut down. This is displayed on the ODU main board LED.

Causas comunes

  • Compressor 3-phase wire connection has open phase or is phase-reversed
  • System is overloaded and compressor current is too high
  • Drive board IPM module is damaged
  • Drive board IPM module’s 15V power supply is lower than 13.5V
  • Drive board 6-line PWM signal and the corresponding element are abnormal
  • Drive board compressor current sampling circuit element is damaged
  • Compressor is damaged

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the compressor 3-phase wire connections for correct phase sequence. Reconnect wires if phased incorrectly.

  2. 2

    Inspect if the system is overloaded; reduce load if possible.

  3. 3

    Check the 15V power supply to the IPM module; ensure it is above 13.5V.

  4. 4

    Replace the drive board if the IPM module or related circuits are suspected to be faulty.

  5. 5

    Replace the compressor if it is damaged.