This error occurs when the outdoor unit is preparing to operate in one mode (e.g., cooling) while an indoor unit is attempting to run in a conflicting mode (e.g., heating). This is common in multi-zone systems.
Haga clic en los pasos para seguir su progreso.
Ensure all indoor units connected to the same outdoor unit are set to the same operating mode (or compatible modes in a multi-zone system).
If using a central controller or home automation system, verify that it's not sending conflicting mode commands.
Power cycle the entire HVAC system by turning off the main power for a few minutes.
After restarting, set all units to a consistent mode and observe.
If the issue persists, review the system's operational settings and consult the Intesis gateway or Samsung system manual.