CodeRegistry
Marcas
  1. Inicio
  2. Samsung
  3. Air Conditioning
  4. E466, E483, E488
About·Privacy·Terms

CodeRegistry — Tu biblioteca global de soluciones técnicas.

Por su seguridad, siga siempre los manuales oficiales del fabricante. CodeRegistry es un sitio independiente y no está afiliado a las marcas citadas.

E466, E483, E488

E466, E483, or E488 — Power supply or voltage sensor error

Samsung · Air Conditioning

¿Qué significa E466, E483, E488 ?

These codes indicate problems related to the power supply, DC Link voltage levels (either too low or too high), or a fault with the AC input voltage sensor. This can prevent the unit from operating correctly.

Causas comunes

  • Incorrect or loose power connection.
  • Fault in the input power supply (e.g., incorrect voltage for single-phase or 3-phase).
  • Reactor or its connecting wires are faulty or incorrectly connected.
  • Defective fuses in the EMI PBA.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Turn off the power to the unit.

  2. 2

    Check the main power connection to the unit and ensure all wires are correctly and firmly connected, with no jointed power connections or interchanged communication wires.

  3. 3

    Verify that the input power voltage is correct for your system (e.g., 220Vac for single-phase, 380Vac for 3-phase).

  4. 4

    If the error persists after checking connections and power, turn off the power again and check the reactor and its connecting wires for any damage, scratches, or loose terminals.

  5. 5

    If there is a defective fuse in the EMI PCB, professional service is needed for replacement.

  6. 6

    If the problem continues, professional assistance is required to inspect internal components like the Inverter PCB.

Ver todos los códigos en este manual (94)
Datos técnicos verificados. Última actualización: April 2026

Fallas relacionadas

COND temperature sensor errorCondenser temperature sensor error — Outdoor coil temperature sensor faultCommunication errorCommunication error — Indoor/outdoor inverter main MICOM communication lostCommunication error after trackingCommunication error after finishing tracking — System communication issue following a tracking process
Fuente: Samsung Air Conditioning
Open Manual (Page 157)Buscar más códigos en este manual