Schneider Electric · EVlink Smart Wallbox Charging Stations Troubleshooting
When the door and trap are opened during a specific reset procedure, the indicator lights turn red, signaling entry into troubleshooting mode.
Haga clic en los pasos para seguir su progreso.
Open the door, then open the trap.
Open the contact; the indicator lights will turn red.
Press the right-hand stop button for about 10 seconds until the right-hand red indicator light goes out and the right-hand green indicator light blinks.
Release the button.
Quickly press the green push-button during the subsequent 10 green light blinks to launch the return to factory settings.