Battery equalization was enabled but did not occur

Battery equalization did not occur — Controller must complete a bulk/absorption cycle first

Schneider Electric · MPPT 80

¿Qué significa Battery equalization was enabled but did not occur ?

The battery equalization cycle has not started even though it was enabled. The charge controller requires completion of a bulk or absorption charging phase before equalization can begin.

Causas comunes

  • The charge controller must complete a bulk/absorption cycle before it can initiate an equalization cycle.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Allow the charge controller to complete its current charging cycle (bulk/absorption).

  2. 2

    Check the status of the equalization cycle in InsightLocal.

  3. 3

    Refer to the 'Equalizing Batteries' section for detailed information.

  4. 4

    Verify that the battery type and settings support equalization.

Ver todos los códigos en este manual (34)
Datos técnicos verificados. Última actualización: April 2026

Fallas relacionadas

10Output Under-voltage Immediate — The DC Output Voltage is too low11Output Under-voltage — The DC Output Voltage is too low2Capacitor Over Temperature — The Capacitors are too hot
Fuente: MPPT 80