Yellow LED

Yellow LED lit — Pump warning, still operating but not as expected

Grundfos · ALPHA2 GO Pumps

What does Yellow LED mean?

When the warning and alarm symbol on the operating panel turns yellow, the pump is in a warning state. It continues to run, but its performance may not be optimal, potentially leading to issues like insufficient heating. An error code will alternate on the display.

Common Causes

  • Minor issue affecting performance
  • Blocked rotor (potentially indicated by PWM feedback)
  • Insufficient heating or discomfort in the system

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Look for a specific error code alternating on the pump's display.

  2. 2

    Connect to the Grundfos GO app to obtain a detailed error description.

  3. 3

    If the operating panel is in power saving mode, press the Selection button to reveal the error code.

  4. 4

    Follow the specific troubleshooting guidance provided by the app for the identified error code.

Browse all codes in this manual (17)
Verified technical data. Last updated: April 2026

Related Faults

132E3 / Code 132 — Pump configuration corrupted or missing25E9 / Code 25 — Incorrect PWM configuration35Code 35 — Air in media (Grundfos GO only)
Source: Grundfos ALPHA2 GO Pumps
Open Manual (Page 20)Search more codes in this manual