[25] Input overcurrent of the drive module

Error 25 — Drive module input overcurrent

Haier · Air Conditioning

What does [25] Input overcurrent of the drive module mean?

The compressor drive module's input current is too high, exceeding 32A for double-fan models or 27A for single-fan models. If this occurs 3 times in an hour, it will lock the system.

Common Causes

  • Incorrect compressor wiring
  • The power module is bad
  • The compressor is bad

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Solve or correct any failures according to relative information.

  2. 2

    Check compressor wiring.

  3. 3

    Check if the power module is bad.

  4. 4

    Check if the compressor is bad.

Browse all codes in this manual (103)
Verified technical data. Last updated: April 2026

Related Faults

1Error Code 1 — Outdoor PCB EEPROM fault10Error Code 10 — Defrost sensor fault11Error Code 11 — Compressor suction temperature sensor fault
Source: Haier Air Conditioning
Open Manual (Page 31)Search more codes in this manual