What does 28-36 mean?

These codes indicate a failure in a liquid or gas temperature sensor connected to an indoor unit's Electronic Expansion Valve (EEV) circuit. The specific sensor affected is identified on the outdoor unit's Error Code Decal.

Common Causes

  • Defective temperature sensor (liquid or gas)
  • Loose or damaged sensor wiring
  • Sensor resistance out of calibration
  • Faulty PCB connection

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Identify the specific malfunctioning sensor using the Error Code Decal.

  2. 2

    Check the sensor wiring connection to the PCB.

  3. 3

    Test the sensor's resistance; if out of range, replace the sensor.

  4. 4

    If a port is available, a sensor from an unused port can be temporarily swapped.