4

Error Code 4 — Communication failure between IPM and PCB

Haier · Air Conditioning

What does 4 mean?

The Inverter Power Module (IPM) is not able to communicate with the main circuit board (PCB). This prevents them from coordinating operations.

Common Causes

  • Wiring issue between IPM and PCB
  • Faulty IPM
  • Faulty PCB

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the wiring and connections at CN9 on the PCB and CN15 on the IPM.

  2. 2

    Verify correct voltage at the IPM CN15 connection.

  3. 3

    If voltage is correct but communication fails, replace the IPM.

  4. 4

    If voltage is incorrect, replace the PCB.