5

Error Code 5 — Compressor overload protection

Haier · Air Conditioning

What does 5 mean?

The IPM is protecting the compressor from an overload condition. This indicates the compressor is working too hard and risks damage.

Common Causes

  • Low building power supply voltage
  • Restrictions in the system
  • Non-condensable gases in the system
  • Blocked coil (outdoor or indoor)
  • Excessive load on the system
  • Refrigerant overcharge

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the building's power supply voltage.

  2. 2

    Inspect for restrictions in the refrigeration circuit.

  3. 3

    Clean indoor and outdoor coils.

  4. 4

    Verify the refrigerant charge is correct.