F4 (8 flashes)

F4 (8 flashes) — Overheat Protection for Discharge Temperature

Haier · Air Conditioning

What does F4 (8 flashes) mean?

This protection activates when the compressor discharge temperature exceeds 110°C. It can be caused by refrigerant issues, faulty sensors, or electronic expansion valve problems.

Common Causes

  • Electronic expansion valve defective
  • Faulty thermistor (discharge sensor)
  • Faulty PCB
  • Refrigerant leak

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the power, then restart the air conditioner.

  2. 2

    Measure the temperature at the compressor's exhaust sensor after startup.

  3. 3

    If the temperature exceeds 110°C shortly after startup, suspect a refrigerant leak or high system load.

  4. 4

    If malfunctions occur after running, but the measured temperature is below 110°C, the discharge sensor may be faulty and need replacement.

Browse all codes in this manual (103)
Verified technical data. Last updated: April 2026

Related Faults

1Error Code 1 — Outdoor PCB EEPROM fault10Error Code 10 — Defrost sensor fault11Error Code 11 — Compressor suction temperature sensor fault