C1D0111 - Starter circuit short to ground
The engine starter circuit has a short to ground. The engine cannot be started.
C1D0115 - Starter circuit short to battery or open
The engine starter circuit has a short to battery or an open circuit. The engine starter cannot be controlled, and cutting cannot continue.
C1D0211 - AUX2 circuit short to ground
The AUX2 circuit has a short to ground. AUX2 cannot be controlled by the HMI.
C1D0215 - AUX2 circuit short to battery or open
The AUX2 circuit has a short to battery or an open circuit. AUX2 cannot be controlled by the HMI.
C1D0311 - Blade clutch circuit short to ground
The blade clutch circuit has a short to ground. The blade clutch cannot be controlled by the HMI, and the blade might remain engaged or disengaged.
C1D0315 - Blade clutch circuit short to battery or open
The blade clutch circuit has a short to battery or an open circuit. The blade clutch cannot be controlled by the HMI, and the blade might remain engaged or disengaged.
C1D0611 - Water pump circuit short to ground
The water pump circuit has a short to ground. The water pump cannot be turned on.
C1D0615 - Water pump circuit short to battery or open
The water pump circuit has a short to battery or an open circuit. The water pump cannot be controlled by the HMI and may not turn on.
C1D0811 - AUX1 circuit short to ground
The AUX1 circuit has a short to ground. AUX1 cannot be controlled by the HMI.
C1D0815 - AUX1 circuit short to battery or open
The AUX1 circuit has a short to battery or an open circuit. AUX1 cannot be controlled by the HMI.
C1D0911 - Working light circuit short to ground
The working light circuit has a short to ground. The working light cannot be turned on.
C1D0915 - Working light circuit short to battery or open
The working light circuit has a short to battery or an open circuit. The working light cannot be controlled by the HMI and may not turn on.
C1D0C11 - Ignition circuit short to ground (Deutz engine)
The ignition circuit has a short to ground, specific to Deutz engines. The engine cannot be started.
C1D0C15 - Ignition circuit short to battery or open (Deutz engine)
The ignition circuit has a short to battery or an open circuit, specific to Deutz engines. The engine cannot be started.
C1D0D11 - Hydraulic lift pump circuit short to ground
The hydraulic lift pump circuit has a short to ground. The hydraulic lift pump cannot be used for raising the blade.
C1D0D15 - Hydraulic lift pump circuit short to battery or open
The hydraulic lift pump circuit has a short to battery or an open circuit. The hydraulic lift pump cannot be used for raising the blade.
C1D0E11 - Hydraulic lowering valve circuit short to ground
The hydraulic lowering valve circuit has a short to ground. The hydraulic lowering valve cannot be used for lowering the blade.
C1D0E15 - Hydraulic lowering valve circuit short to battery or open
The hydraulic lowering valve circuit has a short to battery or an open circuit. The hydraulic lowering valve cannot be used for lowering the blade.
C1E0111 - Blade depth sensor signal short to ground
The blade depth sensor signal has a short circuit to ground. The blade depth cannot be displayed, and the blade depth stop function cannot be used.
C1E0112 - Blade depth sensor signal short to battery
The blade depth sensor signal has a short circuit to the battery. The blade depth cannot be displayed, and the blade depth stop function cannot be used.
C1E0511 - E-track position sensor circuit short to ground
The E-track position sensor has a short circuit to ground. The machine can continue cutting, but the E-track position cannot be detected until this fault is resolved.
C1E0512 - E-track position sensor circuit short to battery
The E-track position sensor has a short circuit to the battery. The machine can continue cutting, but the E-track position cannot be detected until this fault is resolved.
C1F0111 - E-track motor A circuit short to ground
E-track motor A has a short circuit to ground. Cutting can continue, but the E-track cannot be used for drift compensation until this fault is resolved.
C1F0112 - E-track motor A circuit short to battery
E-track motor A has a short circuit to the battery. Cutting can continue, but the E-track cannot be used for drift compensation until this fault is resolved.
C1F0211 - E-track motor B circuit short to ground
E-track motor B has a short circuit to ground. Cutting can continue, but the E-track cannot be used for drift compensation until this fault is resolved.
C1F0212 - E-track motor B circuit short to battery
E-track motor B has a short circuit to the battery. Cutting can continue, but the E-track cannot be used for drift compensation until this fault is resolved.
C1F0513 - E-track motor circuit open
The E-track motor circuit is open. Cutting can continue but the E-track cannot be used for drift compensation until this fault is resolved.
C1F0521 - E-track motor circuit overload
The E-track motor circuit is overloaded. Cutting can continue but the E-track cannot be used for drift compensation until this fault is resolved.
C1F0522 - E-track motor output current openload
The E-track motor output circuit has an open load. Cutting can continue but the E-track cannot be used for drift compensation until this fault is resolved.
P060742 - IOC MPU general memory failure
The I/O Controller Microprocessor Unit (MPU) has experienced a general memory failure. The engine cannot be started, and no machine functions can be controlled.
P060745 - IOC MPU program memory failure
The I/O Controller Microprocessor Unit (MPU) has experienced a program memory failure. The engine cannot be started, and no machine functions can be controlled.
SPN codes (e.g., SPN 63345) - Engine related fault displayed
The machine's display shows an engine-related fault code, identified by an 'SPN' number. These codes indicate specific issues with the engine's operation and require further investigation.
U100087 - I/O Controller no CAN communication
There is no CAN communication with the I/O Controller. The engine cannot be started, and no machine functions can be controlled.
U100088 - I/O Controller software download failed
The software download for the I/O Controller has failed. The engine cannot be started, and no machine functions can be controlled.
U100187 - Engine ECU no CAN communication
There is no CAN communication with the Engine ECU. Cutting cannot continue, and no information is available from the ECU. The engine can start but RPM cannot be controlled.