What does d1 mean?

The boiler is not receiving the expected feedback voltage signal from the LSM 5 unit. This unit is typically involved in controlling the exhaust flap, affecting safe flue gas operation.

Common Causes

  • The wiring connecting the LSM 5 unit is incorrect, damaged, or disconnected.
  • The exhaust flap is stuck, obstructed, or not operating correctly.
  • A malfunction of the LSM 5 unit itself.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the wiring of the LSM 5 unit for any damage, loose connections, or incorrect installation.

  2. 2

    Inspect the exhaust flap for any obstructions or mechanical issues that might prevent its movement.

  3. 3

    Ensure all electrical connections to the LSM 5 unit are secure and properly seated.

  4. 4

    If wiring and the flap appear functional, the LSM 5 unit may require professional inspection or replacement.