6 red flashes, 2 green flashes — High heat-sink temperature

Lennox · Communicating Systems

What does 62 mean?

The temperature inside the inverter's heat sink has exceeded its safe limit. The system will slow down to cool it, and if unsuccessful, the compressor and fan will stop. This can lead to a system lockout if it occurs repeatedly.

Common Causes

  • Inverter heat sink temperature exceeded limit
  • Loose screws holding the heat sink
  • Poor contact between heat sink and control board

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Wait five minutes for capacitors to discharge.

  2. 2

    Check and tighten the screws holding the heat sink to the inverter control board.

  3. 3

    If the condition was moderate, it may clear automatically. If critical, disconnect and reconnect power to the outdoor unit to restart.