Error 23 — Compressor drive module temperature too high

Lennox · EL18KSLV Series Outdoor Units

What does 23 mean?

The compressor drive module is overheating. This is detected by a sensor on the module's heat sink. Causes include refrigerant overcharge or a blocked coil.

Common Causes

  • Overcharge of refrigerant
  • Excessively plugged outdoor coil
  • IPM sensor open or shorted
  • Non-condensable gas in system

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check and correct refrigerant charge if overcharged.

  2. 2

    Clean the outdoor coil thoroughly.

  3. 3

    Ensure the IPM heat sink is clean and free of debris.

  4. 4

    Verify the IPM temperature sensor is functioning correctly.