U6

Outdoor Board LED1 (green) blinks four times and LED2 (red) blinks two times alternately - Abnormality of current sensor (P.B.)

MHI · Air Conditioning

What does U6 mean?

During startup or operation, the outdoor unit's LED1 (green) blinks four times and LED2 (red) blinks two times alternately, indicating an abnormality of the current sensor on the P.B. board.

Common Causes

  • Abnormality of current sensor (P.B.).
  • Faulty current sensor.
  • Wiring issue to the current sensor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the wiring of CN52C and CNAF for secure and correct connections.

  2. 2

    Ensure that the current sensor itself is properly installed and not physically damaged.

  3. 3

    Re-check the error by turning off the main power, waiting, and turning it back on.

  4. 4

    If the issue persists, the current sensor or P.B. board may need to be inspected by a technician.

Browse all codes in this manual (124)
Verified technical data. Last updated: April 2026

Related Faults

00Outdoor Board LED only green lights up after startup - No outdoor unit of address 0 / Remote controller transmission wire open1OPERATION INDICATOR lamp blinks 1 time (Pattern A) - Indoor/outdoor unit communication error (Transmitting error - Outdoor unit)14OPERATION INDICATOR lamp blinks 14 times (Pattern A) - Other errors