1-time blink (recall mode)

Outdoor Unit Recall: 1-time blink - Indoor/outdoor communication, receiving error

Mitsubishi Electric · Air Conditioners

What does 1-time blink (recall mode) mean?

When the outdoor unit failure mode recall function is active, the indoor unit's upper lamp blinks once, then stays OFF for 2.5 seconds. This indicates that normal signals cannot be received from the inverter P.C. board for 3 minutes, or incorrect signals were received consistently.

Common Causes

  • Miswiring between indoor and outdoor units
  • Serial signal error
  • Inverter P.C. board malfunction

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Ensure the failure mode recall function is active to observe the correct blinking pattern.

  2. 2

    Turn off the power supply to the air conditioner, wait a few minutes, then turn it back on to attempt a reset.

  3. 3

    Check all wiring connections between the indoor and outdoor units for miswiring or loose connections.

  4. 4

    After troubleshooting, recall the failure mode again and press the EMERGENCY OPERATION switch to delete the memorized abnormal condition.

  5. 5

    Release the failure mode recall function by turning OFF and ON the power supply, or by pressing the RESET button on the remote controller.

  6. 6

    If the problem persists, contact a qualified service technician for further assistance.

Browse all codes in this manual (40)
Verified technical data. Last updated: April 2026

Related Faults

1-time blink 2.5 seconds OFF (Outdoor unit operates)1-time blink 2.5 seconds OFF — Frequency drop by current protection (Outdoor unit operates)1-time blink every 2.5 seconds1-time blink every 2.5 seconds — Outdoor unit overcurrent protection10-time blink 2.5 seconds OFF10-time blink 2.5 seconds OFF — Outdoor fan motor fault