The left lamp of the OPERATION INDICATOR blinks seven times, followed by a 2.5-second pause. This indicates that the inverter P.C. board or the outdoor electronic control P.C. board cannot properly read data in its nonvolatile memory.
Click steps to track your progress.
Turn OFF the power supply to the unit.
Contact a qualified service technician for diagnosis.
The manual recommends replacing the inverter P.C. board or the outdoor electronic control P.C. board.