8B

8B — Compressor temperature thermistor (TH1) open/short

Mitsubishi Electric · MXZ Air Conditioners

What does 8B mean?

This error indicates a fault with thermistor TH1, which monitors the compressor temperature. The sensor or its wiring is either open (broken circuit) or shorted (incorrect resistance).

Common Causes

  • Damaged compressor thermistor (TH1).
  • Loose or corroded thermistor connection.
  • Faulty wiring leading to the thermistor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the main power to the outdoor unit by switching off its dedicated circuit breaker.

  2. 2

    Locate thermistor TH1 on the compressor and carefully inspect its wiring connections for any looseness, corrosion, or signs of damage.

  3. 3

    If visible, ensure the thermistor probe is correctly seated and making good contact against the compressor surface.

  4. 4

    Power cycle the unit by turning the breaker back on after inspection.

  5. 5

    This typically requires a qualified service technician to test the thermistor's resistance and replace it if faulty.

Browse all codes in this manual (40)