8E

8E — Ambient temperature thermistor (TH4) open/short

Mitsubishi Electric · MXZ Air Conditioners

What does 8E mean?

This error indicates a problem with thermistor TH4, which measures the outdoor ambient temperature. The sensor or its wiring is either open (broken circuit) or shorted (incorrect resistance).

Common Causes

  • Damaged ambient temperature thermistor (TH4).
  • Loose or corroded thermistor connection.
  • Faulty wiring leading to the thermistor.
  • Thermistor physically damaged or obstructed.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the main power to the outdoor unit by switching off its dedicated circuit breaker.

  2. 2

    Locate thermistor TH4, typically exposed to ambient air, and inspect its wiring connections for damage or looseness.

  3. 3

    Ensure the thermistor is not physically damaged or covered by debris.

  4. 4

    Power cycle the unit by turning the breaker back on after inspection.

  5. 5

    A service technician is usually required to test and replace the thermistor if it's malfunctioning.

Browse all codes in this manual (40)
Verified technical data. Last updated: April 2026

Related Faults

7seg LED (not lit)7-segment LED not lit — Multi controller board power issue8181 — Compressor temperature trouble8282 — Superheat due to low discharge temperature trouble
Source: Mitsubishi Electric MXZ Air Conditioners
Open Manual (Page 57)Search more codes in this manual