CodeRegistry
Brands
  1. Home
  2. Mitsubishi Electric
  3. MXZ Air Conditioners
  4. 8G
About·Privacy·Terms

CodeRegistry — Your global library for technical solutions.

For your safety: always follow the equipment manufacturer’s official manuals. CodeRegistry is an independent help site and is not affiliated with the brands listed here.

8G

8G — Heat sink temperature thermistor (THM) open/short

Mitsubishi Electric · MXZ Air Conditioners

What does 8G mean?

This error indicates a fault with thermistor THM, which monitors the heat sink temperature. This suggests an open or short circuit in the sensor or its wiring.

Common Causes

  • Damaged heat sink temperature thermistor (THM).
  • Loose or corroded thermistor connection.
  • Faulty wiring leading to the thermistor.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the main power to the outdoor unit by switching off its dedicated circuit breaker.

  2. 2

    Locate thermistor THM on the heat sink and inspect its wiring connections for damage or looseness.

  3. 3

    Ensure the thermistor probe is securely attached to the heat sink.

  4. 4

    Power cycle the unit by turning the breaker back on after inspection.

  5. 5

    A technician is usually needed to test the thermistor's resistance and replace it if faulty.

Browse all codes in this manual (40)
Verified technical data. Last updated: April 2026

Related Faults

7seg LED (not lit)7-segment LED not lit — Multi controller board power issue8181 — Compressor temperature trouble8282 — Superheat due to low discharge temperature trouble
Source: Mitsubishi Electric MXZ Air Conditioners
Open Manual (Page 57)Search more codes in this manual