Inv. err. 262 — Compressor is blocked: Power transistor too hot

Nibe · Air Conditioning

What does 262 mean?

The Intelligent Power Module (IPM) has shown a fault output signal 5 times within 60 minutes, indicating the power transistor is too hot. This requires checking the 15V supply to the inverter.

Common Causes

  • Incoming power supply interference
  • Service valve closed
  • Insufficient amount of refrigerant
  • Compressor fault
  • Defective inverter board in F2040/AMS

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the 15V supply to the inverter for stability.

  2. 2

    Ensure the service valve is open.

  3. 3

    Verify refrigerant levels.

  4. 4

    Inspect for compressor or inverter board faults.

  5. 5

    Contact a qualified technician.