Compressor is operational/alarm lamp flashing

Compressor light flashing — Alarm in cooling circuit

Nibe · Air Conditioning

What does Compressor is operational/alarm lamp flashing mean?

The compressor light flashes to indicate an alarm has occurred in the cooling circuit. This means one of the pressostats has cut out. It may also indicate standby mode if the compressor is blocked.

Common Causes

  • A pressostat has tripped in the cooling circuit
  • The system is in standby mode with the compressor blocked

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check if the 'Compressor is operational/alarm' lamp is flashing.

  2. 2

    If the lamp is flashing, a pressostat may have tripped. Locate the high pressure pressostat (usually accessible via the filter box).

  3. 3

    Press the button on top of the high pressure pressostat to reset it.

  4. 4

    If the problem persists, switch the heat pump off and then on again to clear the fault code.

  5. 5

    Ensure mode '3' is not set, as this can cause related issues.

Browse all codes in this manual (95)
Verified technical data. Last updated: April 2026

Related Faults

107Sensor flt: BT7 HW sens top 107 — Sensor fault: Hot water sensor151Sen flt: CL11- BT51 pool temp sensor 151 — Sensor fault: Pool temperature sensor152Sen flt: CL12- BT51 pool temper- ature sensor 152 — Sensor fault: Pool temperature sensor
Source: Nibe Air Conditioning
Open Manual (Page 12)Search more codes in this manual