212

Alarm 212 - Low lp cooling (Low low-pressure in cooling circuit)

NIBE · S-Series Heat Pumps

What does 212 mean?

The Heat Pump has registered 5 repeated alarms for low low-pressure in the cooling circuit within 4 hours. This indicates an issue with the cooling system's pressure.

Common Causes

  • Poor flow in the cooling circuit.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the system's circulation pump for proper operation and ensure it is not blocked.

  2. 2

    Inspect any relevant filters for blockages or debris and clean them.

  3. 3

    Ensure there is sufficient water volume in the heating medium system.

  4. 4

    If the problem persists, contact a qualified NIBE service technician for inspection of the refrigerant circuit.

Browse all codes in this manual (55)
Verified technical data. Last updated: April 2026