H97 — Outdoor fan motor mechanism lock

Panasonic · Air Conditioner Panasonic PRO Club

What does H97 mean?

The outdoor fan motor has locked or shown abnormal feedback twice within 30 minutes. This suggests the fan motor is obstructed or malfunctioning.

Common Causes

  • Outdoor fan motor lock or feedback abnormal

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the outdoor fan motor's lead wire and connector.

  2. 2

    Ensure the fan motor is not locked or obstructed.