F16

F16 — Total running current protection (Outdoor unit)

Panasonic · Aquarea Heat Pumps

What does F16 mean?

The outdoor unit's total running current has exceeded a safe limit, activating its protection mechanism. This occurs if the high current condition repeats 3 times within 20 minutes, causing the OFF/ON control panel LED to blink.

Common Causes

  • Excess refrigerant in the system.
  • Defective outdoor PCB (Printed Circuit Board).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Turn off the power supply to the unit at the main breaker for at least 5 minutes, then restore power.

  2. 2

    Monitor the unit for any reappearance of the error code after restarting.

  3. 3

    If the error persists, contact a qualified technician to check refrigerant levels and inspect the outdoor PCB.