What does bit4 - ContactorState mean?

The status of the contactor is incorrect, indicating a fault or discordance.

Common Causes

  • The contactor is stuck.
  • Wiring issue with auxiliary contacts.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check that the contactor is not stuck.

  2. 2

    Verify the wiring of auxiliary contacts.

  3. 3

    If the contactor is stuck, have your vehicle checked as there might be a short-circuit in the on-board charger.

  4. 4

    Consider replacing the contactor.