EVlink City — Green indicator lights blink after beep

EVlink City — Green indicator lights blink after beep — Restarting after reset

Schneider Electric · EVlink Smart Wallbox Charging Stations Troubleshooting

What does EVlink City — Green indicator lights blink after beep mean?

The charging station emits a long beep and its green indicator lights blink. This occurs after a reset procedure and indicates the station is restarting.

Common Causes

  • Completion of a factory reset procedure.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Close the trap contact and the door.

  2. 2

    Wait for the charging station to start, which takes about a minute.

  3. 3

    If at step 3 of the reset procedure all right-hand indicator lights were off, close the trap contact and restart the procedure.

  4. 4

    If only the right-hand green indicator light blinked at step 4, perform the reset procedure on the left side, then the right.