InsightLocal indicates an input over voltage error

InsightLocal indicates an input over voltage error — PV panels are producing voltage levels outside operating specifications

Schneider Electric · MPPT 80

What does InsightLocal indicates an input over voltage error mean?

InsightLocal is reporting an input over-voltage error. This typically occurs when the voltage from the PV panels is too high for the charge controller, often due to cold weather.

Common Causes

  • The PV panels are producing voltage levels that are outside the operating specifications for the charge controller.
  • Extreme cold temperatures for the region.
  • Too many PV panels in series, requiring reconfiguration.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    This condition will likely correct itself when the panels warm up and the voltage decreases.

  2. 2

    If it occurs regularly, the installation may have too many PV panels in series.

  3. 3

    Consult the 'Electrical Specifications' for the charge controller's operating range.

  4. 4

    Consider reconfiguring the PV array to lower the voltage if the problem persists.