Siemens · SINAMICS V70 Drives
This alarm indicates that the tool clamping process for the spindle has exceeded the allowed monitoring time, leading to a failure in clamping the tool. This can be caused by various electrical, mechanical, or pneumatic issues.
Click steps to track your progress.
Using PLC status monitoring, check if the input state of I1.6 on interface X101 is normal.
Inspect interface X101 on the back of the PPU and ensure the connection of pin 8 is secure and not broken.
Verify that pin 10 of interface X101 is properly connected to 0 V (ground).
Check if the air pressure supply is sufficient for tool clamping operations.
Test the spindle tool clamping switch for proper operation and ensure it is not stuck or faulty.
Press the specified key on the MCP (Machine Control Panel) to cancel the alarm after addressing the underlying fault.