Hardware limit Case 1

Hardware limit fault: Hardware limit switch alarm appears on PPU

Siemens · SINAMICS V70 Drives

What does Hardware limit Case 1 mean?

An alarm is displayed on the PPU indicating that a hardware limit switch has been triggered, preventing further axis movement in that direction.

Common Causes

  • Axis has reached or crossed the hardware limit switch
  • Faulty or damaged hardware limit switch

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Press and hold down the designated key on the PPU while simultaneously pressing the axis traversing key to move the feed axis in the opposite direction.

  2. 2

    Continue moving the axis away from the hardware limit switch until the alarm clears.

  3. 3

    If the fault still exists after clearing the alarm, check the hardware limit switches on the machine; verify their connection with a multimeter and check for damage.

Browse all codes in this manual (38)
Verified technical data. Last updated: April 2026

Related Faults

700010Alarm 700010 - Handwheel active700012Alarm 700012 - Spindle is braking700014Alarm 700014 - Spindle gear change timed out