3501, 3601, or 3701

Event 3501, 3601, or 3701 with red LED glowing — Ground fault detected in PV system

SMA · Sunny Boy Inverters

What does 3501, 3601, or 3701 mean?

The red LED is glowing and one of these event numbers is displayed, indicating a ground fault in your PV system. This means the electrical insulation from the PV system to ground is defective or insufficient.

Common Causes

  • Damage to PV array cables or insulation
  • Moisture or debris compromising insulation
  • Faulty PV module or string

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Immediately turn off the DC load-break switch on the inverter.

  2. 2

    Do not touch any parts of the PV array substructure or frame.

  3. 3

    Only touch PV array cables on their insulation.

  4. 4

    Contact a qualified installer or SMA Service to diagnose and repair the ground fault safely.