All LEDs off

All LEDs are off — Overnight shutdown or insufficient PV voltage

SMA · Sunny Boy Inverters

What does All LEDs off mean?

The inverter is in standby mode, typically due to insufficient input voltage for operation, such as during the night. If this occurs during a sunny day with good solar irradiation, it indicates a problem with the PV voltage.

Common Causes

  • Too low input voltage (normal at night).
  • Insufficient PV voltage during daytime.
  • Inverter manually set to STOP mode.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    If this occurs during a sunny day, contact your installer to have the PV voltage checked.

  2. 2

    Ensure the PV panels are clean and free from obstructions that might reduce light reaching them.

  3. 3

    Verify the inverter has not been manually set to STOP mode, which would prevent it from operating.