Two (2) red blinks

Two red blinks — Earth assurance fault, high earth resistance detected, charging disabled

Tesla Wall Connector · (Gen 3)

What does Two (2) red blinks mean?

The Wall Connector continuously checks for a safe earth connection. If high resistance is detected, it will lock out charging and display an error code of two red blinks.

Common Causes

  • High impedance detected in the earth conductor.
  • Improper earthing setup in the installation.
  • Earthing system configured incorrectly for TT or IT grids.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the Wall Connector is properly connected to earth.

  2. 2

    Ensure the earth connection is bonded correctly in the upstream power supply.

  3. 3

    Check all physical connections, including terminals and junction boxes.

  4. 4

    If charging on a TT or IT grid, check the ground monitor settings.