F49

F49 Fault — eBUS short circuit or overload

Vaillant · ecoTEC plus Boilers

What does F49 mean?

A short circuit or overload has been detected on the eBUS communication system, or two power supplies with different polarities are connected to the eBUS.

Common Causes

  • Short circuit on eBUS
  • eBUS overload
  • Two power supplies with different polarities on the eBUS

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the wiring into the eBUS for any damage or short circuits.

  2. 2

    Ensure that only Vaillant controls are connected to the eBUS.

  3. 3

    Verify the polarity of any connected power supplies to the eBUS (requires specialist tools).

  4. 4

    If issues persist, the PCB may be faulty (contact a technician).