F.348

F.348 — Burner in fault state: Gas modulation valve issue

Viessmann · Vitodens 100-W Boiler

What does F.348 mean?

The burner is in a fault state related to the gas modulation valve. This may occur in systems with multiple boilers or indicate a flue issue.

Common Causes

  • Incorrect 'Multiple connections' setting for common flue system (multiple boilers)
  • Restricted flue system flow
  • Faulty gas fan unit

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    If multiple boilers share a common flue, check that the 'Multiple connections' setting in the commissioning assistant is correct.

  2. 2

    Check the flue system for any obstructions or restrictions in flow.

  3. 3

    Reset the boiler by briefly turning off and on its power supply. If the fault persists, contact a qualified heating engineer.