F1

Fault F1 (Detailed 135) — Burner fault: flue gas temperature exceeded limit

Viessmann · Vitodens 200/222 Boilers

What does F1 mean?

The burner is in fault mode because the maximum flue gas temperature limit of 230°F (110°C) has been exceeded. This is a critical safety shutdown indicating potential overheating or restricted exhaust.

Common Causes

  • Maximum flue gas temperature exceeded 230°F (110°C) limit

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the heating system fill level and add water if it is low.

  2. 2

    Bleed air from the heating system to remove any trapped air.

  3. 3

    Check the circulation pump to ensure it is operating correctly.

  4. 4

    Check the boiler water temperature sensor and its cable for proper function and connection.

  5. 5

    Allow the vent system to cool down completely before pressing the reset button R on your boiler.