28

28 — System supply temperature sensor cable broken (low-loss header)

Viessmann · Vitodens 200-W B2HB Boiler

What does 28 mean?

The boiler is regulating without a supply temperature sensor for the low-loss header because its cable is broken.

Common Causes

  • Broken cable connected to the low-loss header sensor
  • Loose connection at the low-loss header sensor
  • Incorrect coding setting if no low-loss header sensor is present

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Visually inspect the connecting cable of the low-loss header sensor for any breaks, cuts, or loose connections.

  2. 2

    Ensure all wiring connections to the low-loss header sensor are secure.

  3. 3

    If no low-loss header sensor is installed, ensure coding address '52' is set to '0'.

  4. 4

    If the cable is damaged or the fault persists, contact a qualified heating technician to repair or replace the cable or sensor.