125

125 — No circulation safety trip

Baxi · Duotec+ GA Compact Boilers

What does 125 mean?

The boiler has shut down due to a lack of water circulation, detected by a temperature sensor. This is a safety measure to prevent overheating.

Common Causes

  • Blocked pump or faulty pump operation
  • Air trapped in the heating circuit
  • Closed valves preventing flow

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Press and hold down the Reset button for 2 seconds to try clearing the fault.

  2. 2

    Check the system pressure and top up if necessary as per the 'FILLING THE SYSTEM' section.

  3. 3

    Bleed any radiators in the system to remove trapped air. Ensure all radiator valves are fully open.

  4. 4

    If the fault persists, contact an Authorised Service Centre to check pump operation and circulation.