5247

Alarm Z2 electric cassette E2 tripped overheat protection / pressure switch

Bosch · Heat Pumps

What does 5247 mean?

The electric cassette for zone 2 has triggered its overheat protection or the system pressure switch has indicated low pressure (below 0.5 bar) in the air module. This prevents damage to the unit.

Common Causes

  • Low system pressure or air trapped in the heating system.
  • Clogged system filter or filter ball (SC1).
  • Poor circulation within the heat transfer or heating system.
  • Overheat protection or pressure switch (MC1) failure.
  • Heat curve or hot water temperature settings are too high.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the system pressure. If low, vent the heating system as per instructions in your manual and top up with water.

  2. 2

    Clean the system filter/filter ball SC1. Refer to your manual for instructions on filter cleaning.

  3. 3

    Review your heat curve and hot water temperature settings; adjust them if they are excessively high.

  4. 4

    Ensure all adjuster valves and radiator thermostats are correctly set for good circulation.

  5. 5

    If the alarm persists after these steps, contact a qualified technician for further inspection.